Converting from a vented to an unvented system

What a vented-to-unvented conversion actually involves, the measurement that decides whether it is viable, and the alternatives.

Short answer

The incoming main’s flow rate determines whether conversion is viable. The work involves a new mains cold feed, the full unvented control set, D1 and D2 discharge pipework, removal of the loft tank and its pipework, and notification under Building Regulations.

Measure first

Everything about this decision rests on one measurement, and it takes ten minutes.

  1. Static pressure at the stopcock with nothing running.
  2. Dynamic flow rate with the stopcock fully open, measured with a flow cup or a bucket and a stopwatch.
  3. Compare against the cylinder’s requirement. Every unvented cylinder specifies a minimum flow and pressure for satisfactory operation.
  4. Think about peak conditions, not the quiet afternoon when the test was done. What does the main deliver at seven in the morning?
If the flow is marginal, the honest answer is no

An unvented cylinder delivers mains pressure to every outlet, but it cannot deliver more water than the main supplies. Convert a house with a poor incoming supply and you get impressive-feeling pressure that runs out the moment a second outlet opens. We would rather tell you at survey than after installation, and it is the most common reason we advise against a conversion.

When the mains is not adequate

Three genuine options rather than proceeding regardless:

Upgrade the supply pipe

If the incoming main from the boundary is an old narrow pipe, replacing it in a larger diameter raises the ceiling on everything downstream. It is real work – excavation from the boundary to the house – and it is sometimes the right answer, particularly if it also resolves poor cold pressure throughout. Your water company may contribute to replacing the section on their side, and it is worth asking before committing.

Fit an accumulator

A vessel that stores mains water under pressure, released during peak demand. It converts a supply that is adequate on average but insufficient at peak into one that performs. Genuinely elegant, less well known than it deserves to be, and it needs space for the vessel.

Keep the vented system and fit a pump

Frequently the best value answer. A correctly specified shower or whole-house pump solves the pressure complaint – which is usually what prompted the conversation – at a fraction of the cost and disruption. See shower types and water pressure.

What the conversion actually involves

  1. Survey and measurementFlow and pressure, cylinder position, discharge route, and where the new mains feed will run.
  2. Size the new cylinderFrom peak demand, with attention to coil area as well as volume – see sizing a hot water cylinder.
  3. Plan the discharge pipeworkD1, tundish and D2 to a safe termination, with fall and equivalent length calculated. This frequently constrains where the cylinder can go, and occasionally determines whether the conversion is possible at all.
  4. Run a new mains cold feedOf adequate diameter, from the incoming main to the cylinder position. On an older house this can be the largest single element of the work.
  5. Remove the old cylinderAnd the loft tank and its associated pipework – feed, vent, and often a second small tank serving the heating.
  6. Install the new cylinder and control setPressure reducing valve, expansion vessel, expansion relief, temperature and pressure relief, thermostats.
  7. Alter the heating connectionsThe heating system may have been open-vented via the loft tank. Removing the tank means the heating becomes a sealed system, which needs its own expansion vessel, pressure gauge and filling loop. This is frequently overlooked in quotes.
  8. Alter the outletsTaps and showers specified for low pressure may need changing – they will work at mains pressure but some are not rated for it, and some will be noisy.
  9. Commission, notify and certifyFilled, vented, temperatures verified, benchmark completed, and the work notified under Building Regulations.

The consequences people do not anticipate

  • The heating system becomes sealed. If the heating was fed and vented via the loft tank, removing the tank changes it fundamentally. It needs an expansion vessel, a pressure gauge, a filling loop and a pressure relief valve. This is real work and a real cost, and it belongs on the quote.
  • Low-pressure taps and showers. Fittings specified for gravity may be noisy, may deliver far more flow than intended, and some are not rated for mains pressure at all.
  • No water in a mains failure. You lose the stored buffer the tank provided.
  • Cold pressure changes too, because everything now comes off the main. Generally an improvement; occasionally it reveals that the main is the limitation.
  • The loft space is freed, which most people count as a benefit.
  • Annual servicing becomes a requirement, where a vented cylinder was largely maintenance-free.
  • The discharge pipework has to go somewhere, and on some cylinder positions there is genuinely no compliant route.
Ask what the quote includes for the heating system

A conversion quote that covers the cylinder and its controls but says nothing about sealing the heating system has left out a substantial item. On a house where the heating was open-vented through the loft tank, that work has to happen.

Is it worth it?

Strong case Weak case
Good measured mains flow Marginal mains flow
Multiple bathrooms, simultaneous use One bathroom, modest use
Poor upstairs shower pressure that matters Pressure complaint solvable with a pump
Wanting the loft space back Loft tank causing no problem
Cylinder due for replacement anyway Existing cylinder recently replaced
A compliant discharge route exists No sensible route for D2
Staying in the house Moving soon

The honest summary: where the mains supports it and the cylinder is due anyway, conversion is frequently an excellent improvement. Where the mains is marginal, or where the real complaint is one weak shower, there are cheaper answers that work better.

Considering converting? The ten-minute flow measurement comes first, and it settles the question either way.

Call 07506 070316

Questions we get asked about this

Can any house be converted to unvented?

Only where the incoming mains flow supports it and there is a compliant route for the discharge pipework. Both are survey questions and either can rule it out.

Is the conversion just a cylinder swap?

No. It involves a new mains cold feed, the full control set, discharge pipework, removal of the loft tank and its pipework, and frequently converting the heating system to sealed operation.

Will my existing taps and showers still work?

They will work, and some may not be ideal. Fittings specified for gravity can be noisy at mains pressure and some are not rated for it. It is worth reviewing the outlets as part of the project.

What happens to my heating system?

If it was open-vented via the loft tank, it becomes a sealed system and needs an expansion vessel, pressure gauge, filling loop and relief valve. This is a real item that should be on the quote.

Is it notifiable work?

Yes, under Building Regulations Part G3, and it requires specific competence. You should receive a certificate – keep it.

What if my mains is not good enough?

Upgrade the supply pipe from the boundary, fit an accumulator, or keep the vented system and fit a pump. The last is frequently the best value if the real complaint is one weak shower.

Regulations and standards referenced on this page