F-Gas leak testing

Systems above certain refrigerant charges must be leak checked at set intervals, with records kept. We handle both.

Short answer

Leak checking frequency is determined by a system’s CO2e – refrigerant charge multiplied by its global warming potential. We calculate it, carry out the checks, and set up the records the regulations require.

Does it apply to you?

It depends on one figure, and it is straightforward to establish.

  1. Find the nameplate on the outdoor unit. It carries the refrigerant type and the charge in kilograms.
  2. Multiply the charge by that refrigerant’s global warming potential, and divide by 1000. That gives CO2e in tonnes.
  3. Compare against the current thresholds. Below the lowest, there is no mandatory periodic leak checking. Above it, checking is required at an interval that shortens as CO2e rises.

Because refrigerant GWPs vary by a large factor, two physically similar systems can have completely different obligations. It is worth doing the arithmetic rather than assuming.

A single domestic split is usually below the threshold

Most single split systems in a house fall below the lowest CO2e threshold, so mandatory periodic leak checking does not apply. What does apply regardless of size is that refrigerant may only be handled by a qualified person working for a certified company, and that a system which needs topping up has a leak that must be repaired rather than simply refilled.

Where it does apply domestically

  • Larger multi-split systems, where the combined charge is substantial.
  • VRF in a large house, which is uncommon domestically and does happen.
  • Older systems on high-GWP refrigerant, which reach a threshold at a much smaller physical charge than a modern R32 system would.
  • Home offices and outbuildings with substantial cooling, where the installation is effectively commercial in scale.
  • Any refrigeration – a wine room, a cold store, a garage chiller – which counts exactly as air conditioning does.

For commercial premises the obligations are more extensive and the duty sits explicitly on the equipment operator – see F-Gas compliance.

What a leak check involves

It is not a visual inspection and it is not the same as a service.

  1. Carried out by a qualified personWorking for a certified company. Both are required – employing qualified engineers is not sufficient on its own.
  2. Using an appropriate methodA calibrated electronic leak detector, or an indirect method based on system parameters where the standards permit it.
  3. Covering the parts prone to leakageJoints, valves, seals, flare connections, service ports, and anywhere subject to vibration.
  4. RecordedDate, method, result and who carried it out – including checks that found nothing.
  5. Repair without undue delay where a leak is foundAnd a re-check within the defined period afterwards to verify the repair worked.

A maintenance visit does not automatically constitute a leak check, and conflating the two is a common source of gaps. Both should happen and both should be recorded separately – see air conditioning servicing.

Why a system that needs topping up has a problem

A refrigeration circuit is sealed. There is no such thing as routine refrigerant consumption. If a system is low, refrigerant has escaped, and it will keep escaping.

  • Topping up without repairing is not permitted, and deliberate release is an offence.
  • It is money evaporating. On a high-GWP refrigerant, increasingly expensive money as the phase-down progresses – see the refrigerant phase-down.
  • Performance degrades before the system fails, so you are running inefficiently in the meantime.
  • Low charge damages the compressor, because refrigerant carries the oil that lubricates it.
  • The leak is usually findable. Most split system leaks are at flare connections, which is a workmanship issue from installation showing up years later.

So the right response to a system that is not cooling as well as it did is to find out whether it is low and why, rather than to add gas and carry on.

Records

Where a system is above the threshold, records must be kept covering the refrigerant type and quantity installed, any added or recovered and why, who did the work, the dates and results of every check, and the measures taken at end of life.

Two practical points that apply even below the threshold, because they are useful rather than merely required:

  1. Keep your own copy, not just your contractor’s. If you change contractor, the history is yours and you are entitled to it.
  2. Record the charge at installation, including any additional refrigerant added for long pipe runs. Without an accurate charge figure you cannot calculate CO2e, and reconstructing it later is awkward.

See what an F-Gas logbook must contain.

Not sure whether it applies to you? Two figures off the nameplate settle it, and it takes one visit.

Call 07506 070316

Questions we get asked about this

Does F-Gas apply to my home air conditioning?

Mandatory periodic leak checking usually does not for a single domestic split, because the charge is below the threshold. The handling and certification requirements apply regardless of size.

How do I work out my CO2e?

Refrigerant charge in kilograms multiplied by that refrigerant’s global warming potential, divided by 1000. Both figures are on the outdoor unit nameplate.

Can I just top up the refrigerant?

No. Handling refrigerant requires qualification and company certification, and topping up a system with a known leak without repairing it is not permitted. A system that is low has a leak.

Does refrigeration count as well as air conditioning?

Yes. A wine room, a cold store or a garage chiller counts exactly as air conditioning does, and these are the systems most commonly overlooked.

Is a service the same as a leak check?

No. They are separate things with separate records. A maintenance visit does not automatically constitute a leak check.

What if my system uses an older refrigerant?

It will keep running. What changes is the cost and availability of refrigerant if it ever needs recharging, which makes a future leak much harder to justify repairing. Worth knowing when planning replacement.

Sources

Regulations and standards referenced on this page

How it works

What happens when you call

01

Call and describe it

You speak to an engineer, not a call centre. Most jobs can be narrowed down on the phone.

02

We look at it properly

A real diagnosis before a price, and a straight answer if it is not worth doing.

03

A written quote

Itemised, so you can see what you are paying for.

04

The job, and the paperwork

Certificates where the work needs them, and what will need attention next.

Coverage

Where we do this work

Across Norwich and the whole of Norfolk. If you are on the edge of the county, call and ask — we will tell you honestly whether we are the right people.

  • Norwich
  • Wymondham
  • Dereham
  • Attleborough
  • Aylsham
  • North Walsham
  • Cromer
  • Diss
  • Loddon
  • Long Stratton
  • Watton
  • King's Lynn

All areas we cover →

Need this doing?

Call and describe the problem — you will speak to an engineer, not a call centre. Written quotes, no estimates over the phone.

Call now Get a quote